Rotor bar pre-fault detection in the squirrel cage induction motors

2015

The paper deals with a diagnosis technique to detect and monitor incipient faults in the rotor bars of squirrel gage induction motors. The failure mode analysis is performed monitoring the motor axial vibrations. To accomplish the task, the authors present a mathematical model that allows relating the occurrence and the severity of the faults to the presence and the magnitude of some frequency components of the axial vibration spectrum. To validate the proposed approach, the results obtained by applying the mathematical model are compared with the ones obtained by experimental tests done on both healthy and faulty motors.

Squirrel cage motorVibration analysisSettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciFault detectionSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Double squirrel cage induction motors: A new approach to detect rotor bar failures

2013

The purpose of this paper is to present a diagnosis technique, for rotor broken bar in double cage induction motor, based on a combined use of frequency sliding and wavelet transform analysis, to isolate the contribution of the rotor fault components issued from vibration signals in a single frequency band. The validity of the proposed diagnosis approach is not limited to the analysis under steady-state operating conditions, but also for time-varying conditions where rotor fault components are spread in a wide frequency range.

Vibration signaturedouble squirrel cage motorbroken barSettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciSettore ING-INF/07 - Misure Elettriche E Elettronicheinduction motor
researchProduct

Quantitative Rotor Broken Bar Evaluation in Double Squirrel Cage Induction Machines under Dynamic Operating Conditions

2013

Advanced monitoring techniques leading to fault diagnosis and prediction of induction machine faults, operating under non-stationary conditions have gained strength because of its considerable influence on the operational continuation of many industrial processes. In case of rotor broken bars, fault detection based on sideband components issued from currents, flux, instantaneous control or power signals under different load conditions, may fail due to the presence of inter-bar currents that reduce the degree of rotor asymmetry, especially for double squirrel cage induction motors. But the produced core vibrations in the axial direction, can be investigated to overcome the limitation of the …

discrete wavelet transformEngineeringbusiness.industryRotor (electric)Squirrel-cage rotorBar (music)squirrel cage motorSettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciFault (power engineering)FAULT DIAGNOSISFault detection and isolationPower (physics)law.inventionVibrationTime-Frequency AnalysisControl theorylawAC Machine Condition monitoring Double cage rotor fault diagnostics induction motor wavelet TransformbusinessInduction motor
researchProduct